XY Stages

ALD-115-E1P

1
XYStage
Estimate separately
Direction of travel XY axis two directions
Travel ±75mm
Stage size 125mm×125mm
YESRoHS対応状況

Product documentation

Description

Is XY automatic stage of precision in using the ball move in the guide bush.
You can use the automatic positioning various sensors, for work.
Limit adjustment of the position sensor is the sensor and is available pre-origin.

Specifications

Direction of travel XY axis two directions
Travel ±75mm
Stage size 125mm×125mm
Motor used Equivalent to PK543NBW (5 wire type pentagonal connection 0.75A / phase)
Resolution 0.002mm
Lead screw 1mm
Guiding method Ball bushing
Travel accuracy HV Straightness(horizontal and vertical)0.08mm
Positioning accuracy 0.10mm(no load),0.60mm(4kg on load)
Repeatability ±0.015mm
Lost motion 0.03mm
Perpendicularity 0.06mm
Moment rigidity -
Load capacity 98N(10kgf)
Weight 11kg
Maximum speed 16mm/s(8,000pps)
Material / Surface treatment Aluminium alloy / White alumite
ORG sensor Normally open contact (make contact, A contact), Photo sensor
Pre-ORG sensor Normally closed contact (break contact, B contact), Photo sensor
Limit sensor Normally closed contact (break contact, B contact), Photo sensor
Compatible cable ACB-STD2,ACB-STD3

Connection method- Cable, Controller and Driver -

Operating principle of the Sensor and Timing Chart